Operation Manual

For

NDJ-1 Rotary Viscometer

MADE  IN  CHINA

Thank you for using NDJ-1 Rotary Viscometer. NDJ-1 is easy to use, in order to install and operate accuray, and make full use of product features, we suggest you to read the manual before using.

· The company possesses the final interpretation power.

· The company reserves the power of amending technical rules without prior notice.

· The company reserves the power to amend the manual without further notice.

· May not be translated into other languages, reproduction prohibited without written permission. 

               

               Cataloge

1General……………………………………………………

2Main technical data…………………………………………

3Principle………………………………………………

4Installation……………………………………………………

5Operation procedures………………………

6Precaution………………………………………………

Packing List ……………………………………………………

1. General

NDJ-1 rotary viscometer is a new instrument used for determining the liquid viscose capacity and the absolute viscosity. NDJ-1 has been widely used to determine and measure the liquid viscosity in many applications such as grease, painting, plastic, pharmacy and adhesives. It is a precision instrument to monitor and control the stable quality of products in the manufacturing.

2. Main technical data

1) Measurement range: 10-100.000 mPa·s 

2) Rotor specification: 0, 1, 2, 3, 4, 5, five kind rotor (0# rotor could measure the viscometer from low viscometer to 0.1 mPa·s)

3) Measurement error: ±5% (Newton liquid)

4) Power supply: Voltage--220±22V, Frequency50 Hz±0.5Hz

5) Dimensions: 300 mm ×300 mm × 450 mm

6) Net weight: 1.5 Kg (the base not included)

3. Principle

1) Figure 1Synchronous motor rotates with stable rate, connect scale disk, through hairspring and rotating shaft, drives rotors to rotate. The rotors will subject to a torque moment proportional to liquid viscosity because of the liquid viscose hysteresis. The torque moment will be measured by the sensors and processed into the viscosity and shown on the display.

2) Rate can be changed by using gear system and clutch, operated by rotary knob, four optional velocity.

3) According to different equipments, different rotors (Five rotors: NO.0-NO.4) will be attached, it can be select with the velocity according to the viscosity of the liquid.

4) The fixed control gear of pointer are used for accurate reading. When the rate is so fast (30 rpm, 60 rpm) that you can not get the reading while it rotated, press pointer joystickfix the pointer in order to get the reading.

5) The rotor bracket is used for the protection of rotors and the stability of the measurement, a more reliable measuring result can be made by using the protection bracket. 

6) It can be used as a portable instrument, assigned fixed bracket and elevating system. Generally, it should be fixed when determine small amount or the temperature is fixed in the laboratory.

7) The instrument has gears and damping elevate mechanism. It is stable for instrument lifting.

8) The whole set of instrument has good quakeproof packing to ensure the precision of instrument.

Installation

1. Take out the bracket, package, stanchion and so on from the packaging.

2. Screw the column to the threaded hole behind the bracket, and put the tooth profile surface in the column facing front the bracket. Screw the hex nut tight by wrench to prevent the column running.

3. Rotational move the lifting chuck knob to check the flexibility and self-looking of lifting chuck. Found the lifting chuck too loosen and too tight phenomenon, can be used hex nut wrench to adjust the tight screw. So that it can lift from top to bottom. And it is suitable for tight to prevent the situation of automatically falling after installing the viscometer.

4. Take out viscometer form package and mount it on the lifting collettight it by handle setscrew to avoid loosen(as level as possible), link the power supply, take away the rubber band on the pointer joystick, screw the nut of protecting-cap loosen under the instrument, take away the protecting -cap.

5. Adjust the adjustment screw and put the rotor into the liquid to be measured till the level mark on the rotor reach the liquid surface.

Operation procedures

1. Prepare the liquid to be measured and put it into a glass beaker or a right angle container with the diameter not smaller than 70 mm, height not smaller than 130mm, take care of the liquid temperature.

2. Mount the protection bracket on instrument, turning right for mounting, turning left for removing.

3. Screw the selected rotor into connecting rod, turning right for mounting, turning left for removing , Adjust the lifting screw and put the rotor into the liquid to be measured till the level mark on the rotor reach the liquid surface. Connect power supply, turn on the equipment, screw the speed knob, select velocity, relax pointer joystick, reading data can be displayed (about 20~30 seconds) when the pointer becomes stable. Press the pointer joystick after pointer becoming stable, cut power supply, then get the reading data. If the pointer isnt in reading window after motor stop, you can press pointer joystick unceasingly, open or close the motor time after time, after practice, you can operate it familiarly.

4. When the reading data is too high or too low, the rotor or the rate can be changed, make sure the reading is between 20 and 80.

5. Choice of range, coefficient, rotor and rate:

5.1 Estimate approximay the viscose range, then select the rotor and the velocity based on the range table given below:

For example, the viscosity of liquid is about 3000 mPa·s the settings should be as following:  

rotor 2 # with velocity of 6 rpm,

rotor 3 # with velocity 0f 30 rpm

5.2 If the viscosity of liquid can not be estimated, it should take a high value for real measurement, the rotor selection should be made from smaller to larger with their number from higher to lower. In general, high viscosity should use smaller rotor with slower velocity, lower viscosity use lager rotor with faster velocity.

5.3 Coefficient: the reading must be multiplied the specific coefficient in the coefficient table in order to get the absolute viscosity.

   That is: 

            absolute viscosity

            coefficient

            reading ( deflection angle)

   5.4 Amendment of frequency error: when the power frequency is inaccurate, you can amendment it according to the formula below:

      Actual viscosity= instruction viscosity*nominal frequency/ actual frequency

Velocity

Range

Rotor

60

30

12

6

1

100

200

500

1000

2

500

1000

2500

5000

3

2000

4000

10000

20000

4

10000

20000

50000

100000

   5.5 

5.6 Coefficient table: 

        Rpm

Rotor

60

30

12

6

1

1

2

5

10

2

5

10

25

50

3

20

40

100

200

4

100

200

500

1000

 

Precaution

1. This instrument is limited to the room temperatures

2. This instrument should be used under the designed voltage and frequency and their allowable error ranges, or incorrect results could be resulted.

3. Using the bracket fix the instrument in order to determine accuray. Handheld operation: keep the instrument stable and level.

4. Care should be taken for mounting or removing rotors, slightly and lift the connecting screw bolt to avoid a transverse force acting on rotor to cause it bending.

5. The instrument mounted with rotor should not be revolved.

6. Don’t run the motor when the pointer joystick is not pressed.

7. Keep cleaned on screws and connecting points between rotor and connecting bolt rod, or a unstable rotation could be caused in the real measurement.

8. Use hand to hold the instrument when lifting up or moving down to avoid dropping it.

9. After completing measurement each time, the rotor should be fully cleaned (rotor should be removed from instrument for cleaning), then place it on the protection bracket.

10. Unauthorized removing or replacing the instrument part, and applying lubricates are not allowable.

11. When moving or shipping instrument, put on the yellow caver cap and lift the connecting bolt rod and screw the bolt on the cap tightly.

12. Suspension, emulsion or polymer and other high viscosity liquids are non-Newton liquids, their viscosity will change with shear velocity and time, it is normal for their measured inconsistent results under the selected rotor and velocity and time, and it is not resulted from the instrument problems (in general, the rotor and velocity and time should be specified for non-Newton liquids).  

13. The cautions should be taken for followings to obtain a good measuring reault:

(1) Accuray control the temperature of liquid to be measured;

(2) Make temperature of rotor and protection bracket same as liquid;

(3) Ensure the liquid homogeneity and without bubbles;

(4) Put the rotor located on the center of the liquid container in real measurement;

(5) Remove bubbles adhered on the rotor when put it into liquid;

(6) When change the rotor or rate, keep between 30~90 as possible.

(7) Use rotor protection bracket for measurement;

(8) Ensure rotor and connecting screw rod cleaned;

(9) Amend according to the amending formula when power frequency is not exact.

(10) When pointer is stable, reading with the same angle of view.

(11) Adjust level bubble exactly, move the instrument slowly, keep the instrument stable.

(12) Strictly follow the operation instruction for measurement.

Packing List

1) NDJ-1 Digital Rotary Viscometer           1 Qt.

2) Rotors, 1#, 2#, 3# and 4#                   1 Qt of each

3) Protection bracket                       1 Qt.

4) Bracket                                1 Qt.

5) Adjusting screw                         3 Qt.

6) Operation manual                        1 Qt.

7) License                                1 Qt.

8) Warranty card                           1 Qt.

上海平軒科學儀器有限公司

上海平軒科學儀器有限公司

工廠地址:上海市嘉定區南翔德園路1259弄18號

©2018 版權所有:上海平軒科學儀器有限公司  備案號:滬ICP備10019381號-1  總訪問量:1610477  站點地圖  技術支持:化工儀器網  管理登陸

主站蜘蛛池模板: 午夜视频在线免费观看 | 中国孕妇变态孕交xxxx | 少妇伦子伦精品无码styles | 国产精品视频色拍拍 | 国产又黄又猛又粗又爽的A片动漫 | 中文字幕va一区二区三区 | 夜夜添无码试看一区二区三区 | 亚洲 小说区 图片区 都市 | 亚洲国产精品一区二区久久hs | 国产成人久久av免费 | 欧美最猛黑人xxxx黑人猛交98 | 欧美老熟妇乱xxxxx | 婷婷国产精品 | 黄色小视频在线观看 | 9l蝌蚪porny中文自拍 | 免费精品一区二区三区在线观看 | 色噜噜狠狠色综合欧洲 | 四虎永久在线精品国产馆v视影院 | 欧美一区精品 | 日本精a在线观看 | 欧美一级片在线播放 | 久久久噜噜噜久久中文字幕色伊伊 | 肉体暴力强伦轩在线播放 | 久久久久久国产精品免费免费狐狸 | 国产乡下三级全黄三级bd | 免费视频精品一区二区 | 亚洲欧美国产精品久久久久久久 | 国产偷人爽久久久久久老妇app | 日韩一本之道一区中文字幕 | 男女啪啪免费视频 | 天天操天天爱天天干 | 成人综合久久综合 | 国产成人精品久久二区二区91 | 高清精品一区二区三区 | 久久婷婷是五月综合色狠狠 | 热久久这里只有精品 | 麻豆国产人妻欲求不满谁演的 | 97视频免费播放观看在线视频 | 亚洲精品美女视频 | 成人h动漫精品一区二区无码 | 免费黄网站在线播放 | 国产欧美一区二区三区久久人妖 | 亚洲日韩成人 | 毛片毛片毛片毛片毛片怎么 | 亚洲精品乱码久久久久久久久久久久 | 少妇被又大又粗又爽毛片久久黑人 | 夭天曰天天躁天天摸在线观看 | 成人高清 | 一级鲁丝片 | 色天天天天综合男人的天堂 | 亚洲三级视频在线观看 | 成人一区二区三区四区 | 隔壁人妻偷人bd中字 | 国产高清在线精品免费 | 成人黄色免费视频 | 热er99久久6国产精品免费 | 国产亚洲精品无码成人 | 全免费A敌肛交毛片免费 | 99热热热| 人妻少妇精品无码专区 | 亚洲私人无码综合久久网 | 草草影院发布页 | 日本肥老妇色xxxxx日本老妇 | 亚洲日韩乱码中文无码蜜桃臀 | 天天摸天天射 | www.久久色 | 色婷婷综合久久久久中文一区二区 | 91社区在线高清 | 色偷偷色噜噜狠狠成人免费视频 | 国产乱子伦农村xxxx | 亚洲在线免费观看 | wwwwww日本| 91在线入口 | 999久久久 | 寡妇被老头舔到高潮的视频 | 国内精品视频一区二区三区八戒 | 亚洲精品久久7777777 | 国产精品国产亚洲区艳妇糸列短篇 | 不卡中文一二三区 | 亚洲最大的成人网 | 正在播放国产大学生情侣 | 国产做a| 欧美二区三区 | 精品三级久久久久电影我网 | 免费欧美黄色网址 | 日本强好片久久久久久aaa | 免费精品久久久久久中文字幕 | 精品久久久久久久久久久久久久久 | 免费精品美女久久久久久久久久 | 热re66久久精品国产99re | 日产a一a区二区www | 无码一区二区波多野结衣播放搜索 | 在线视频不卡国产在线视频不卡 | 三级视频网址 | 中文字幕在线精品 | 热久久久 | 国产精品久久久久久影视 | 日韩精品一区二区在线观看 | 一区二区三区欧美 |